Journal of Laboratory Physicians
Home About us Ahead of print Current issue Back issues Subscribe Instructions Contact Login 
Wide layoutNarrow layoutPrint this page  Email this page Bookmark this page Small font size Default font size Increase font size 
 
ORIGINAL ARTICLE
Year : 2018  |  Volume : 10  |  Issue : 1  |  Page : 80-84

Evaluation of new indigenous “point-of-care” ABO and Rh grouping device


1 Department of Transfusion Medicine, Medanta - The Medicity, Gurgaon, Haryana, India
2 Department of Transfusion Medicine, Manipal Hospitals, Jaipur, Rajasthan, India

Correspondence Address:
Dr. Aseem Kumar Tiwari
Department of Transfusion Medicine, Medanta - The Medicity, Sector-38, Gurgaon - 122 001, Haryana
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JLP.JLP_71_17

Rights and Permissions

BACKGROUND: Erycard 2.0 is a “point-of-care” device that is primarily being used for patient blood grouping before transfusion. MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. CONCLUSION: Erycard 2.0 can be used as “point-of-care” device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1725    
    Printed39    
    Emailed0    
    PDF Downloaded65    
    Comments [Add]    

Recommend this journal