Journal of Laboratory Physicians
Home About us Ahead of print Current issue Back issues Subscribe Instructions Contact Login 
Wide layoutNarrow layoutPrint this page  Email this page Bookmark this page Small font size Default font size Increase font size 
 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 11  |  Issue : 3  |  Page : 275-280

Multiplex PCR assay for simultaneous detection and differentiation of Entamoeba histolytica, Giardia lamblia, and Salmonella spp. in the municipality-supplied drinking water


1 Department of Laboratory Medicine, Division of Clinical Microbiology and Molecular Medicine, All India Institute of Medical Sciences, New Delhi, India
2 Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
3 Department of Pharmacology, Vanderbilt University, Nashville, Tennessee, USA
4 Department of Obstetrics and Gynecology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA

Correspondence Address:
Prof. Sarman Singh
All India Institute of Medical Sciences, Ansari Nagar, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JLP.JLP_66_18

Rights and Permissions

BACKGROUND: The contamination with Entamoeba histolytica, Giardia lamblia, and Salmonella spp. in drinking water is the most prevalent in Indian subcontinent, but often difficult to detect all these pathogens from the drinking water. MATERIALS AND METHODS: A multiplex polymerase chain reaction (mPCR) method was developed to detect contamination of municipality-supplied drinking water with E. histolytica, G. lamblia, and Salmonella spp. The primers were designed to target small subunit of 16S rRNA type gene of E. histolytica and G. lamblia, and invasive A gene of Salmonella typhimurium. The optimized mPCR assay was applied on 158 municipality-supplied drinking water samples collected from Delhi. RESULTS: Out of total 158 water samples, 89 (56.32%) were found positive for the targeted pathogens by mPCR while conventional methods could be detected only in 11 (6.96%) samples. The mPCR assay showed 100% sensitivity and specificity for these pathogens in comparison with culture and microscopic detection. Of the 89 mPCR-positive samples, G. lamblia, E. histolytica, and Salmonella spp. were present in 35 (22.15%), 26 (16.45%), and 28 (17.72%), respectively. Nine (5.69%) samples were positive for both E. histolytica and G. lamblia, 10 (6.32%) were positive for G. lamblia and Salmonella spp., and 8 (5.06%) had Salmonella spp. and E. histolytica. Nonetheless, 3 (1.89%) samples were positive for all three pathogens. CONCLUSIONS: The present assay is an alternative to conventional methods to serve as highly sensitive, specific, and economical means for water quality surveillance to detect the outbreak caused by E. histolytica, G. lamblia, and Salmonella spp. pathogens.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed185    
    Printed13    
    Emailed0    
    PDF Downloaded29    
    Comments [Add]    

Recommend this journal